©2006 KIB enterprises | Contact Information: Address - 53402 County Road 13 Elkhart, IN. 46514 • Phone - (574) 262-0518

footer100

 

 

 

 

K24-MWL

Schematics
Support

Functions

Allows monitoring of fresh water, grey water, black water and battery levels.   All functions are controlled from one test switch for easy operation.   Optional functions allow monitoring of LP gas, a fourth holding tank and control of the water heater.   All panels also have a lighted switch to control the water pump.

 

 

FunctionsDecorCircuitryPower RequirementsInstallationServiceabilitySchematics

Serviceability

This system is designed for trouble-free operation, however, it is also designed for ease of troubleshooting and service for those few times that may require attention.

The circuit board and faceplate snap into the bezel and plug into the wiring with one connector allowing you to troubleshoot the system within seconds, by unplugging the circuit board and plugging a new one in. No wires ever have to be disconnected from the system and there is no need for any special testers to pinpoint the problem.

Should there be a problem with the circuit board, it can be sent back to KIB for repair while the rest of the system remains wired up. This allows the use of the pump and/or water heater and there are no holes in the wall from the removal of the bezel during that time circuit board is being repaired.

We at KIB belive this will give you and your customers the very best features and trouble-free operation. Not discounting the ease of serviceability, if ever required.

 

Installation

The monitor panel attaches to the wall with four supplied #4 flat head screws and the faceplate with the circuit board snaps into the bezel over the screws for a very clean appearance.

The tanks require a very small pigtail to be attached to the probes requiring only one wire to return to the panel from each tank and one combined ground wire for all the tanks. These wires can be as small as 22 gauge, eliminating the need for a bulky and expensive multi-wire harness to go to each tank.

 

Power Requirements

The system only draws power when a switch is on, causing no battery drain while not in use. The monitor panel display consumes only 175 ma. maximum with all options and only during the time a switch is pressed. The only other consumption is the draw of your pump and/or the ignition circuit of the water heater, when it is in use.

Circuitry

The electronics use integrated circuit technology with complete voltage regulation, for the most reliable circuit design in the industry.   This assures proper level displays with a wide range of input voltages from 9 VDC all the way up to 35 VDC.   Eliminating erroneous level displays from weak batteries and power surges caused by some generators and converters. The display is lighted by solid-state L.E.D.'s to eliminate burnout problems.

 

Decor

The entire panel is mounted in an ABS bezel with an easy to clean matte finish lexan label for continued good appearance.   The overall size is only 3-9/16 " H x 4-7/8 " W and is only 0.75" thick when mounted on the wall. The monitor can be built with custom labels using your company logo, custom colors, etc. upon approved agreements.